A Novel Multi Slit X-Ray Backscatter Camera Based on Synthetic Aperture Focusing

dc.contributor.author Wieder, Frank
dc.contributor.author Ewert, Uwe
dc.contributor.author Bellon, Carsten
dc.contributor.author Jaenisch, Gerd-Rüdiger
dc.contributor.author Vogel, Justus
dc.date 2018-02-17T22:34:52.000
dc.date.accessioned 2020-06-30T06:53:44Z
dc.date.available 2020-06-30T06:53:44Z
dc.date.issued 2016-01-01
dc.description.abstract <p>A special slit collimator was developed earlier for fast acquisition of X-ray back scatter images. The design was based on a twisted slit design (ruled surfaces) in a Tungsten block to acquire backscatter images. The comparison with alternative techniques as the flying spot and the coded aperture pin hole technique could not prove the expected higher contrast sensitivity. In analogy to the coded aperture technique, a novel multi slit camera was designed and tested. Several twisted slits were parallelly arranged in a metal block. The CAD design of different multi-slit cameras was evaluated and optimized by the computer simulation packages aRTist and McRay. The camera projects a set of equal images per slit to the digital detector array, which are overlaying each other. Afterwards, the aperture is corrected based on a deconvolution algorithm to focus the overlaying projections into a single representation of the object. Furthermore, a correction of the geometrical distortions due to the slit geometry is performed. The expected increase of the contrast-to-noise ratio is proportional to the square root of the number of parallel slits in the camera. However, additional noise has to be considered originating from the deconvolution operation. The slit design, functional principle, and the expected limits of this technique will be discussed.</p>
dc.format.mimetype application/pdf
dc.identifier archive/lib.dr.iastate.edu/qnde/2016/abstracts/259/
dc.identifier.articleid 4894
dc.identifier.contextkey 9228686
dc.identifier.s3bucket isulib-bepress-aws-west
dc.identifier.submissionpath qnde/2016/abstracts/259
dc.identifier.uri https://dr.lib.iastate.edu/handle/20.500.12876/62015
dc.language.iso en
dc.relation.ispartofseries Review of Progress in Quantitative Nondestructive Evaluation
dc.source.bitstream archive/lib.dr.iastate.edu/qnde/2016/abstracts/259/099_A_Novel_Multi.pdf|||Fri Jan 14 22:59:45 UTC 2022
dc.subject.disciplines Computer-Aided Engineering and Design
dc.subject.disciplines Materials Science and Engineering
dc.subject.disciplines Mechanical Engineering
dc.title A Novel Multi Slit X-Ray Backscatter Camera Based on Synthetic Aperture Focusing
dc.type event
dc.type.genre event
dspace.entity.type Publication
relation.isSeriesOfPublication 289a28b5-887e-4ddb-8c51-a88d07ebc3f3
File
Original bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
099_A_Novel_Multi.pdf
Size:
14.46 KB
Format:
Adobe Portable Document Format
Description: