An inductively coupled plasma as an ion source for the determination of trace elements in solutions by mass spectrometry

dc.contributor.author Houk, Robert
dc.contributor.department Department of Chemistry
dc.date 2018-08-17T12:55:15.000
dc.date.accessioned 2020-07-02T06:00:08Z
dc.date.available 2020-07-02T06:00:08Z
dc.date.copyright Tue Jan 01 00:00:00 UTC 1980
dc.date.issued 1980
dc.description.abstract <p>Aerosols of trace elements in solution are injected into an inductively coupled argon plasma to generate a relatively high number density of positive ions derived from the trace elements. A small fraction of these ions is extracted through a pinhole sampling orifice into a differentially pumped vacuum system housing an ion lens and quadrupole mass spectrometer. The positive ion mass spectrum obtained during nebulization of the solvent (1% HNO(,3) in H(,2)O) consists essentially of ArH('+), Ar('+), H(,3)O('+), H(,2)O('+), NO('+), O(,2)('+), HO('+), Ar(,2)('+), Ar(,2)H('+), and Ar('+2). Thus there are few potential interferences from solvent or argon ions above 42 u. The mass spectra of the trace elements studied consists almost entirely of singly charged monatomic (M('+)) or oxide (MO('+)) ions. The various isotopes of those elements studied are detected in the correct relative isotopic abundances. Several trace elements are readily detected in a mass spectrometer scanning mode at 0.05 ug/mL. Analytical calibration curves obtained in a single ion mode are linear over nearly four orders of magnitude with detection limits of 0.001 - 0.01 ug/mL for those elements studied. Rapid sample throughput, direct introduction of solutions, and the capability of direct isotopic determination of trace elements are among the attractive features of this new analytical approach;*USDOE Report IS-T-898. This work was performed under contract W-7405-eng-82 with the Department of Energy and Interagency Agreement IAG-EPA-78-D-X0147 with the Environmental Protection Agency.</p>
dc.format.mimetype application/pdf
dc.identifier archive/lib.dr.iastate.edu/rtd/7378/
dc.identifier.articleid 8377
dc.identifier.contextkey 6310023
dc.identifier.doi https://doi.org/10.31274/rtd-180813-5022
dc.identifier.s3bucket isulib-bepress-aws-west
dc.identifier.submissionpath rtd/7378
dc.identifier.uri https://dr.lib.iastate.edu/handle/20.500.12876/80248
dc.language.iso en
dc.source.bitstream archive/lib.dr.iastate.edu/rtd/7378/r_8019636.pdf|||Sat Jan 15 01:46:53 UTC 2022
dc.subject.disciplines Analytical Chemistry
dc.subject.keywords Chemistry
dc.subject.keywords Analytic
dc.subject.keywords Chemistry
dc.subject.keywords Analytical Chemistry
dc.title An inductively coupled plasma as an ion source for the determination of trace elements in solutions by mass spectrometry
dc.type dissertation
dc.type.genre dissertation
dspace.entity.type Publication
relation.isAuthorOfPublication 72e25a81-2813-4101-9504-8f38266732b7
relation.isOrgUnitOfPublication 42864f6e-7a3d-4be3-8b5a-0ae3c3830a11
thesis.degree.level dissertation
thesis.degree.name Doctor of Philosophy
File
Original bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
r_8019636.pdf
Size:
2.71 MB
Format:
Adobe Portable Document Format
Description: