Energy Use Analysis of Open-Curtain vs. Totally Enclosed Broiler Houses in Northwest Arkansas

dc.contributor.author Liang, Yi
dc.contributor.author Xin, Hongwei
dc.contributor.author Tabler, G.
dc.contributor.author Watkins, Susan
dc.contributor.author Xin, Hongwei
dc.contributor.author Berry, Ivan
dc.contributor.department Agricultural and Biosystems Engineering
dc.date 2018-02-13T04:18:39.000
dc.date.accessioned 2020-06-29T22:37:39Z
dc.date.available 2020-06-29T22:37:39Z
dc.date.copyright Thu Jan 01 00:00:00 UTC 2009
dc.date.embargo 2012-12-13
dc.date.issued 2009-01-01
dc.description.abstract <p>Seventeen years of electricity and propane fuel use data collected from broiler production houses at the University of Arkansas Applied Broiler Research Farm (ABRF) in Northwest Arkansas were analyzed to quantify the relative effect of open-curtain versus totally enclosed housing systems on energy use. The ABRF consists of four commercial-scale 12- × 121-m (40-× 400-ft) houses and raises broilers under standard production contracts. After the first 15 years of production with open-curtain system, all houses were converted to the solid-wall enclosed system with drop ceiling, tunnel ventilation, and cooling pads in early 2006. The renovations led to reduction of the overall building heat loss factor (W·K-1) from 1389 to 586 for the two steel-frame houses and from 1022 to 428 for the two wooden-truss houses. Mean outside temperature (ranging from 14.7°C to 17.5°C or 58.5°F to 63.5°F in annual mean temperature during the 17-year period) and bird age were found to be the major factors affecting propane fuel usage and ventilation fan electricity usage. Electricity for ventilation and lighting comprised about 87% of the total electricity usage. Annual electricity usage was 27% higher with the enclosed system than with the open-curtain system (102 vs. 80 kWh per 1000-kg market bird weight or 46.4 vs. 36.4 kWh/1000 lb), due to loss of natural daylight and increased mechanical ventilation in the enclosed system. Propane use was comparable between curtain-sided and solid-wall housing schemes, averaging 76- and 65-L/1000 kg market bird weight (9.1 vs. 7.8 gal/1000 lb) before and after renovation, respectively. Higher fuel cost resulted in higher fuel expenditure for winter heating than electricity expenditure for summer cooling in this region. With increasing energy costs, analysis of energy use, as conducted in this study, will assist the decision making of growers to improve energy efficiency or explore alternative energy application.</p>
dc.description.comments <p>This article is from <a href="http://elibrary.asabe.org/abstract.asp?aid=27468&t=3&dabs=Y&redir=&redirType=" target="_blank"><em>Applied Engineering in Agriculture</em></a> 25, no. 4 (2009): 577–584.</p>
dc.format.mimetype application/pdf
dc.identifier archive/lib.dr.iastate.edu/abe_eng_pubs/169/
dc.identifier.articleid 1172
dc.identifier.contextkey 3536222
dc.identifier.s3bucket isulib-bepress-aws-west
dc.identifier.submissionpath abe_eng_pubs/169
dc.identifier.uri https://dr.lib.iastate.edu/handle/20.500.12876/906
dc.language.iso en
dc.source.bitstream archive/lib.dr.iastate.edu/abe_eng_pubs/169/Xin_2009_EnergyUseAnalysis.pdf|||Fri Jan 14 21:07:28 UTC 2022
dc.subject.disciplines Agriculture
dc.subject.disciplines Bioresource and Agricultural Engineering
dc.subject.keywords Broiler production
dc.subject.keywords Electricity consumption
dc.subject.keywords Energy cost
dc.subject.keywords Fuel usage
dc.title Energy Use Analysis of Open-Curtain vs. Totally Enclosed Broiler Houses in Northwest Arkansas
dc.type article
dc.type.genre article
dspace.entity.type Publication
relation.isAuthorOfPublication 36e0a8ce-fa2e-4df4-9f67-8d1717122650
relation.isOrgUnitOfPublication 8eb24241-0d92-4baf-ae75-08f716d30801
File
Original bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
Xin_2009_EnergyUseAnalysis.pdf
Size:
562.41 KB
Format:
Adobe Portable Document Format
Description:
Collections