Cumulative Soil Water Evaporation as a Function of Depth and Time

dc.contributor.author Xiao, X.
dc.contributor.author Horton, R.
dc.contributor.author Horton, Robert
dc.contributor.author Sauer, T. J.
dc.contributor.author Heitman, J. L
dc.contributor.author Ren, T.
dc.contributor.department Agronomy
dc.date 2018-01-25T07:47:46.000
dc.date.accessioned 2020-06-29T23:04:48Z
dc.date.available 2020-06-29T23:04:48Z
dc.date.issued 2011-01-01
dc.description.abstract <p>Soil water evaporation is an important component of the surface water balance and the surface energy balance. Accurate and dynamic measurements of soil water evaporation enhance the understanding of water and energy partitioning at the land–atmosphere interface. The objective of this study was to measure the cumulative soil water evaporation with time and depth in a bare field. Cumulative water evaporation at the soil surface was measured by the Bowen ratio method. Subsurface cumulative soil water evaporation was determined with the heat pulse method at fine-scale depth increments. Following rainfall, the subsurface cumulative evaporation curves followed a pattern similar to the surface cumulative evaporation curve, with approximately a 2-d lag before evaporation was indicated at the 3- and 9-mm soil depths, and several more days' delay in deeper soil layers. For a 21-d period in 2007, the cumulative evaporation totals at soil depths of 0, 3, 9, 15, and 21 mm were 60, 44, 29, 13, and 8 mm, respectively. For a 16-d period in 2008, the cumulative evaporation totals at soil depths of 0, 3, 9, 15, and 21 mm were 32, 25, 16, 10, and 5 mm, respectively. Cumulative evaporation results from the Bowen ratio and heat pulse methods indicated a consistent dynamic pattern for surface and subsurface water evaporation with both time and depth. These findings suggest that heat pulse sensors can accurately measure subsurface soil water evaporation during several wetting–drying cycles.</p>
dc.description.comments <p>This article is published as Xiao, Xinhua, Robert Horton, T. J. Sauer, J. L. Heitman, and Tusheng Ren. "Cumulative soil water evaporation as a function of depth and time." Vadose Zone Journal 10, no. 3 (2011): 1016-1022. doi: <a href="http://dx.doi.org/10.2136" target="_blank">10.2136/vzj2010.0070</a>. Posted with permission.</p>
dc.format.mimetype application/pdf
dc.identifier archive/lib.dr.iastate.edu/agron_pubs/389/
dc.identifier.articleid 1436
dc.identifier.contextkey 11408811
dc.identifier.s3bucket isulib-bepress-aws-west
dc.identifier.submissionpath agron_pubs/389
dc.identifier.uri https://dr.lib.iastate.edu/handle/20.500.12876/4741
dc.language.iso en
dc.source.bitstream archive/lib.dr.iastate.edu/agron_pubs/389/2011_Horton_CumulativeSoil.pdf|||Fri Jan 14 23:54:12 UTC 2022
dc.source.uri 10.2136/vzj2010.0070
dc.subject.disciplines Agriculture
dc.subject.disciplines Hydrology
dc.subject.disciplines Soil Science
dc.title Cumulative Soil Water Evaporation as a Function of Depth and Time
dc.type article
dc.type.genre article
dspace.entity.type Publication
relation.isAuthorOfPublication d3fb0917-6868-417e-9695-a010896cfafa
relation.isOrgUnitOfPublication fdd5c06c-bdbe-469c-a38e-51e664fece7a
File
Original bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
2011_Horton_CumulativeSoil.pdf
Size:
1000.37 KB
Format:
Adobe Portable Document Format
Description:
Collections