Microwave resonant sensor for measurement of ionic concentration in aqueous solutions

dc.contributor.advisor Nicola Bowler
dc.contributor.advisor Nathan M. Neihart
dc.contributor.author Roy, Subhanwit
dc.contributor.department Department of Electrical and Computer Engineering
dc.date 2018-08-11T18:28:18.000
dc.date.accessioned 2020-06-30T03:09:27Z
dc.date.available 2020-06-30T03:09:27Z
dc.date.copyright Sun Jan 01 00:00:00 UTC 2017
dc.date.embargo 2001-01-01
dc.date.issued 2017-01-01
dc.description.abstract <p>Nitrate efflux from agricultural lands in the Midwestern United States mixes with surface streams and creates hypoxic conditions in the Gulf of Mexico, which lead to destruction of aquatic ecosystems. Besides, excess nitrate in drinking water poses a serious threat to human health, including blue baby syndrome, birth defects, and cancer. The current nitrate management techniques are inefficient and expensive, and a major reason for this is the lack of low-cost, effective ionic concentration monitoring systems. The dependence of nitrate concentration on local hydrology means that laboratory techniques yield incomplete data, whereas the available real-time monitoring techniques have drawbacks like exorbitant cost, ion selectivity issues, and others. This research aims to bridge the gap between reliable concentration monitoring and economic feasibility by developing a low-cost, effective, real time ion monitoring system which is field deployable and sensitive to changes in ionic concentration at agriculturally-relevant levels.</p> <p>In this work, a resonant sensor is designed using an open-ended coaxial transmission line which can be evanescently perturbed by a liquid sample and shows a shift in its resonant frequency on change of ionic concentration of the sample. The dimensions of the coaxial resonator are optimized to ensure high sensitivity to changes in the ionic concentration of the sample at relevant concentrations, low manufacturing costs, and small physical dimensions to enable field deployment. The resonant sensor design is followed by the design and optimization of a suitable coupling structure which can take two-port transmission measurements to measure the characteristics of the resonator.</p> <p>Finite Element Analysis (FEA) simulations are carried out using ANSYS HFSS, using as input data the complex permittivity of aqueous solution samples with varying concentrations of nitrate, sulfate, and chloride ions. Deionized water is taken as a reference sample, and a clear correlation between shift in resonant frequency and ionic concentration is observed for each of the three resonant modes studied, with the sensor being highly sensitive to concentration changes at agriculturally relevant concentrations. Appropriate fitting functions are implemented to represent the correlations between resonant frequency and ion concentration, and discussion on the feasibility of the designed sensor for field deployment is presented.</p>
dc.format.mimetype application/pdf
dc.identifier archive/lib.dr.iastate.edu/etd/16205/
dc.identifier.articleid 7212
dc.identifier.contextkey 11457175
dc.identifier.doi https://doi.org/10.31274/etd-180810-5834
dc.identifier.s3bucket isulib-bepress-aws-west
dc.identifier.submissionpath etd/16205
dc.identifier.uri https://dr.lib.iastate.edu/handle/20.500.12876/30388
dc.language.iso en
dc.source.bitstream archive/lib.dr.iastate.edu/etd/16205/Roy_iastate_0097M_17001.pdf|||Fri Jan 14 20:56:42 UTC 2022
dc.subject.disciplines Engineering
dc.subject.keywords dielectric metrology
dc.subject.keywords finite element analysis
dc.subject.keywords low cost
dc.subject.keywords microwave resonant sensor
dc.subject.keywords nitrate monitoring
dc.subject.keywords nondestructive evaluation
dc.title Microwave resonant sensor for measurement of ionic concentration in aqueous solutions
dc.type thesis en_US
dc.type.genre thesis en_US
dspace.entity.type Publication
relation.isOrgUnitOfPublication a75a044c-d11e-44cd-af4f-dab1d83339ff
thesis.degree.discipline Computer Engineering
thesis.degree.level thesis
thesis.degree.name Master of Science
File
Original bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
Roy_iastate_0097M_17001.pdf
Size:
4.66 MB
Format:
Adobe Portable Document Format
Description: