Shear Wave EMAT Thickness Measurements of Low Carbon Steel at 450˚C without Cooling

Thumbnail Image
Date
2016-01-01
Authors
Lunn, Natasha
Potter, Mark
Dixon, Steve
Major Professor
Advisor
Committee Member
Journal Title
Journal ISSN
Volume Title
Publisher
Authors
Research Projects
Organizational Units
Journal Issue
Is Version Of
Versions
Series
Series
Review of Progress in Quantitative Nondestructive Evaluation
Center for Nondestructive Evaluation

Begun in 1973, the Review of Progress in Quantitative Nondestructive Evaluation (QNDE) is the premier international NDE meeting designed to provide an interface between research and early engineering through the presentation of current ideas and results focused on facilitating a rapid transfer to engineering development.

This site provides free, public access to papers presented at the annual QNDE conference between 1983 and 1999, and abstracts for papers presented at the conference since 2001.

Department
Abstract

Ensuring reliability of components operating at high temperature, such as pipelines and boilers, within a variety of industries is of importance in the asset management process, and is implemented via regular inspections and condition monitoring. Performing online inspections without the need for plant shutdown is highly desirable. Development of portable or permanently installed high temperature ultrasonic sensors without sample surface preparation remains a key challenge. There are examples of high temperature piezoelectric sensors operating without cooling, but these usually require welding or brazing. Actively cooled electromagnetic acoustic transducers (EMATs) have previously been used for thickness measurements and defect detection to over 1000 ˚C. High temperature EMAT operation requires active cooling for permanent magnet EMATs [1] or a large electromagnet [2], limiting their use in some industrial settings. Low carbon steel pipelines operating at elevated temperatures often develop a magnetostrictive oxide surface coating (magnetite), which greatly improves EMAT efficiency below the Curie point of the magnetite (~560 ˚C), and we are able to take advantage of this if we can indefinitely operate an EMAT at elevated temperature. In this work, a high temperature shear wave EMAT utilizing a proprietary high field, high Curie point, permanent magnet has been developed to generate ultrasonic thickness measurements on magnetite coated steel at temperatures up to 450 ˚C, without active cooling. Exploiting the high efficiency possible on magnetite coated surfaces, relatively high signal-to-noise ratios, in the region of 25 dB for single shot data, have been measured at 450 ˚C using this technique, despite increased ultrasound attenuation and reduced magnet field strength at elevated temperatures.