Comparison of Scattering Amplitudes from Various Transducers Using Diffraction and Attenuation Corrections

dc.contributor.author Wormley, S.
dc.contributor.author Thompson, Donald
dc.date 2018-02-14T05:30:57.000
dc.date.accessioned 2020-06-30T06:30:02Z
dc.date.available 2020-06-30T06:30:02Z
dc.date.copyright Sun Jan 01 00:00:00 UTC 1984
dc.date.issued 1984
dc.description.abstract <p>As a part of a project to develop an ultrasonic multiviewing transducer which is capable of providing sufficient information for flaw reconstruction, results have been obtained that address certain phases of the required signal processing routine. It is well known that individual ultrasonic transducers show a considerable variation in signal responses. Inasmuch as the multiviewing transducer uses a sparse array of individual transducers arranged in a particular geometry, it becomes important that signal processing routines be developed and applied which overcome these variabilities. There are, of course, several possible sources of variability in transducer performance. These include those of measurement (diffraction, attenuation and effects associated with imperfect deconvolution processes), and those due to fabrication (transducer design, materials, reproducibility of fabrication techniques, etc.). The results presented in this paper address only the former of these two. In particular, they represent a limited experimental assessment of the adequacy of specific data processing procedures for three different transducers and three different samples utilizing Weiner filter concepts and diffraction and attenuation corrections. Use is made of theoretical curves for scattering amplitude as an absolute standard of comparison and therefore as the criterion of adequacy.</p>
dc.format.mimetype application/pdf
dc.identifier archive/lib.dr.iastate.edu/qnde/1984/allcontent/30/
dc.identifier.articleid 2338
dc.identifier.contextkey 5793380
dc.identifier.s3bucket isulib-bepress-aws-west
dc.identifier.submissionpath qnde/1984/allcontent/30
dc.identifier.uri https://dr.lib.iastate.edu/handle/20.500.12876/58656
dc.language.iso en
dc.relation.ispartofseries Review of Progress in Quantitative Nondestructive Evaluation
dc.source.bitstream archive/lib.dr.iastate.edu/qnde/1984/allcontent/30/1984_WormleySJ_ComparisonOfScattering.pdf|||Fri Jan 14 23:26:54 UTC 2022
dc.source.uri 10.1007/978-1-4684-1194-2_30
dc.subject.disciplines Acoustics, Dynamics, and Controls
dc.subject.keywords Ames Laboratory
dc.title Comparison of Scattering Amplitudes from Various Transducers Using Diffraction and Attenuation Corrections
dc.type event
dc.type.genre article
dspace.entity.type Publication
relation.isSeriesOfPublication 289a28b5-887e-4ddb-8c51-a88d07ebc3f3
File
Original bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
1984_WormleySJ_ComparisonOfScattering.pdf
Size:
696.02 KB
Format:
Adobe Portable Document Format
Description: