On-Farm Ventilation Fan Performance Evaluations and Implications

dc.contributor.author Casey, K. D.
dc.contributor.author Gates, Richard
dc.contributor.author Wheeler, E. F.
dc.contributor.author Xin, Hongwei
dc.contributor.author Liang, Y.
dc.contributor.author Pescatore, A. J.
dc.contributor.author Ford, M. J.
dc.contributor.author Xin, Hongwei
dc.contributor.department Agricultural and Biosystems Engineering
dc.date 2021-01-25T21:53:45.000
dc.date.accessioned 2021-02-24T17:51:58Z
dc.date.available 2021-02-24T17:51:58Z
dc.date.copyright Tue Jan 01 00:00:00 UTC 2008
dc.date.issued 2008-07-01
dc.description.abstract <p>Fans are key components of mechanically ventilated poultry housing. When installed, the fan is often fitted with 1 or more accessories, including safety guards, shutters, and discharge cones. These first 2 accessories usually reduce the airflow and fan efficiency, whereas discharge cones improve airflow. Field performance of a fan is further impacted by accumulated dirt on the blades and shutters, mechanical wear, and degree of maintenance. Performance of all ventilation fans on 2 commercial broiler farms was determined during an air emission monitoring project. Each fan was tested using the Fan Assessment Numeration System at a range of static pressures typical of its regular operating range. The performance of otherwise identical fans was shown to vary by up to 24%. This variation in performance is attributed to accumulated dirt and corrosion, differences in the resistance to flow imposed by the shutters, and differences in motor and bearing wear due to run time and aging. A small reduction in fan speed from slipping or worn belts had a large effect on airflow generated by the 1,220-mm (48 in.) diameter fans. The power consumption of each fan was also measured as part of the evaluation process and revealed considerable variation among these fans.</p>
dc.description.comments <p>This article is published as Casey, K. D., R. S. Gates, E. F. Wheeler, H. Xin, Y. Liang, A. J. Pescatore, and M. J. Ford. "On-farm ventilation fan performance evaluations and implications." <em>Journal of Applied Poultry Research</em> 17, no. 2 (2008): 283-295. doi: <a href="https://doi.org/10.3382/japr.2006-00055" target="_blank" title="Persistent link using digital object identifier">10.3382/japr.2006-00055</a>.</p>
dc.format.mimetype application/pdf
dc.identifier archive/lib.dr.iastate.edu/abe_eng_pubs/1178/
dc.identifier.articleid 2462
dc.identifier.contextkey 21251408
dc.identifier.s3bucket isulib-bepress-aws-west
dc.identifier.submissionpath abe_eng_pubs/1178
dc.identifier.uri https://dr.lib.iastate.edu/handle/20.500.12876/92981
dc.language.iso en
dc.source.bitstream archive/lib.dr.iastate.edu/abe_eng_pubs/1178/0-OA_for_2008_Gates_OnFarmVentiliation.pdf|||Fri Jan 14 18:57:57 UTC 2022
dc.source.bitstream archive/lib.dr.iastate.edu/abe_eng_pubs/1178/2008_Gates_OnFarmVentiliation.pdf|||Fri Jan 14 18:57:59 UTC 2022
dc.source.uri 10.3382/japr.2006-00055
dc.subject.disciplines Agriculture
dc.subject.disciplines Bioresource and Agricultural Engineering
dc.subject.disciplines Poultry or Avian Science
dc.subject.keywords air movement
dc.subject.keywords ventilation system maintenance
dc.subject.keywords poultry housing
dc.subject.keywords energy consumption
dc.subject.keywords broiler
dc.subject.keywords layer
dc.title On-Farm Ventilation Fan Performance Evaluations and Implications
dc.type article
dc.type.genre article
dspace.entity.type Publication
relation.isAuthorOfPublication a61fa792-56f2-4397-8a9c-8cbde8d5c3f1
relation.isAuthorOfPublication 36e0a8ce-fa2e-4df4-9f67-8d1717122650
relation.isOrgUnitOfPublication 8eb24241-0d92-4baf-ae75-08f716d30801
File
Original bundle
Now showing 1 - 2 of 2
No Thumbnail Available
Name:
2008_Gates_OnFarmVentiliation.pdf
Size:
661.97 KB
Format:
Adobe Portable Document Format
Description:
No Thumbnail Available
Name:
0-OA_for_2008_Gates_OnFarmVentiliation.pdf
Size:
1.41 MB
Format:
Adobe Portable Document Format
Description:
Collections