Micro and nanopatterned biodegradable polymer films for peripheral nerve regeneration

dc.contributor.advisor Surya K. Mallapragada
dc.contributor.author Miller, Cheryl
dc.contributor.department Theses & dissertations (Interdisciplinary)
dc.date 2018-08-24T18:11:59.000
dc.date.accessioned 2020-06-30T07:09:07Z
dc.date.available 2020-06-30T07:09:07Z
dc.date.copyright Sat Jan 01 00:00:00 UTC 2000
dc.date.issued 2000-01-01
dc.description.abstract <p>Annually over 200,000 surgeries are attempted to repair peripheral nerve damage.1 Without these surgeries, peripheral nerve transections have little hope of reinnervating the effector organ and becoming fully functional if the nerve endings are separated by a centimeter or more. Currently, transections are repaired with nerve autografts removed from one part of the body to repair the injured site. Autografting causes deinnervation of the donor site and tissue availability is limited.;An alternative nerve repair method to grafting is an entubulization method where a conduit is used to connect the nerve endings. The conduit allows for chemical communications between the nerve stumps and also provides physical guidance for the regenerating neurites.;By using a conduit to engineer an artificial environment that mimics the physical and chemical stimulus that promotes peripheral nerve regeneration, faster and more direct regeneration may be possible.;The purpose of this project was to investigate cellular activities that direct and guide peripheral nerve outgrowth in vitro. Micro and nanopatterned biodegradable polymer films of poly(DL-lactide) and poly(lactide-co-g1ycolide) were fabricated to provide physical guidance. The patterned surface was chemically modified with laminin to contribute neurotrophic factors and then seeded Schwann cells, which furnish biological cues.;The results show that Schwann cells and dissociated dorsal root ganglia (DRG) seeded separately on laminin coated micropatterned films of 10 mum groove width by 10 mum or 20 mum groove spacing align well due to the effects of the physical and chemical guidance mechanisms. The Schwann cells experienced 100% alignment on substrates with groove depths ranging from 1.5 to 3.3 mum and dissociated DRG aligned 77 +/- 3% on 3 mum deep patterns and 92 +/- 3% on groove depths of 4 mum. The laminin adsorption caused 8 times more Schwann cells and 5 times more dissociated DRG adhere to the films and the neurites had the added benefit of 3 times more outgrowth.;When simultaneously combining the physical effects of the grooves, the chemical influence of the laminin and biological enhancements from the Schwann cells, the synergistic effects caused the DRG to grow along the direction of the grooves at an accelerated rate.;1Medical Devices and Diagnostic Industry, pg. 3, August 1985.</p>
dc.format.mimetype application/pdf
dc.identifier archive/lib.dr.iastate.edu/rtd/1097/
dc.identifier.articleid 2096
dc.identifier.contextkey 6090456
dc.identifier.doi https://doi.org/10.31274/rtd-180813-767
dc.identifier.s3bucket isulib-bepress-aws-west
dc.identifier.submissionpath rtd/1097
dc.identifier.uri https://dr.lib.iastate.edu/handle/20.500.12876/64174
dc.language.iso en
dc.source.bitstream archive/lib.dr.iastate.edu/rtd/1097/r_3016763.pdf|||Fri Jan 14 18:31:55 UTC 2022
dc.subject.disciplines Biomedical Engineering and Bioengineering
dc.subject.keywords Biomedical engineering
dc.title Micro and nanopatterned biodegradable polymer films for peripheral nerve regeneration
dc.type dissertation
dc.type.genre dissertation
dspace.entity.type Publication
thesis.degree.discipline Biomedical Engineering
thesis.degree.level dissertation
thesis.degree.name Doctor of Philosophy
File
Original bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
r_3016763.pdf
Size:
1.71 MB
Format:
Adobe Portable Document Format
Description: