Ventilation Requirements to Prevent Pit Air Up-Drafting in a Swine Finishing Barn
Date
Authors
Hoff, Steven
Hoff, Steven
Major Professor
Advisor
Committee Member
Journal Title
Journal ISSN
Volume Title
Publisher
Altmetrics
Authors
Research Projects
Organizational Units
Journal Issue
Series
Department
Abstract
Curtain sided deep-pit swine finishing buildings are popular in the industry due to concerns related to odors from outdoor manure storage systems. Local regulators are requesting additional odor reduction from the building. Biofiltration is a technology that reduces odors exhausted from swine buildings if the exhaust air can be controlled. Upward air movement through the slatted floor must be eliminated to treat all pit gasses when the ventilation is operating in a mode with the curtains lowered.
Critical (minimal) pit ventilation rates were determined to insure downward air flow through the slatted floor in a swine finishing barn with 8, 11, 14, 17, 20, 23, and 36 percent floor opening. The critical air velocity through the slatted floor averaged 36.2 ft/min (SD = 1.2 ft/min).
Using a safety factor of 1.5, the design criterion is 50 cfm/pig for pit ventilation rate before the curtains are lowered for full-slatted barns to assure no upward air movement from the pit after the curtains are lowered. This recommendation will provide continuous biofilter treatment of pit gasses for all ventilation modes.
Comments
This proceeding is from Pp. 025-030 in Swine Housings II Proceedings of the 12-15 October 2003 Conference (Research Triangle Park, North Carolina USA), Publication Date 12 October 2003. 701P1303.