Quantitative Multi-Inspection-Site Comparison of Probability of Detection for Vibrothermography Nondestructive Evaluation Data
Quantitative Multi-Inspection-Site Comparison of Probability of Detection for Vibrothermography Nondestructive Evaluation Data
dc.contributor.author | Holland, Stephen | |
dc.contributor.author | Li, Ming | |
dc.contributor.author | Holland, Stephen | |
dc.contributor.author | Meeker, William | |
dc.contributor.author | Meeker, William | |
dc.contributor.department | Statistics | |
dc.date | 2018-02-16T21:12:15.000 | |
dc.date.accessioned | 2020-07-02T06:56:28Z | |
dc.date.available | 2020-07-02T06:56:28Z | |
dc.date.issued | 2011-02-01 | |
dc.description.abstract | <p>This paper describes the estimation of probability of detection (POD) for a vibrothermography inspection procedure. The results are based on a large scale experiment on specimens with two different kinds of metal containing fatigue cracks. The specimens were tested independently at three inspection sites: Iowa State University (ISU), Pratt and Whitney (PW) and General Electric (GE). Despite the substantially different vibrothermography configurations and experimental measurement responses, the estimated PODs as function of crack length and dynamic stress were similar for all three inspection sites, which make quantitative POD comparisons possible across different inspection sites.</p> | |
dc.description.comments | <p>This preprint was published as Ming Li, Stephen D. Holland & William Q. Meeker, "Quantitative Multi-Inspection-Site Comparison of Probability of Detection for Vibrothermography Nondestructive Evaluation Data", <em>Journal of Nondestructive Evaluation</em> (2011): 172-178, doi: <a href="http://dx.doi.org/10.1007/s10921-011-0105-9" target="_blank">10.1007/s10921-011-0105-9</a>.</p> | |
dc.identifier | archive/lib.dr.iastate.edu/stat_las_preprints/90/ | |
dc.identifier.articleid | 1077 | |
dc.identifier.contextkey | 7435753 | |
dc.identifier.s3bucket | isulib-bepress-aws-west | |
dc.identifier.submissionpath | stat_las_preprints/90 | |
dc.identifier.uri | https://dr.lib.iastate.edu/handle/20.500.12876/90388 | |
dc.language.iso | en | |
dc.source.bitstream | archive/lib.dr.iastate.edu/stat_las_preprints/90/2011_MeekerWQ_QuantitativeMultiInspection.pdf|||Sat Jan 15 02:26:42 UTC 2022 | |
dc.subject.disciplines | Statistics and Probability | |
dc.subject.keywords | Center for Nondestructive Evaluation | |
dc.subject.keywords | maximum likelihood | |
dc.subject.keywords | noise interference model | |
dc.subject.keywords | POD | |
dc.subject.keywords | sonic infrared inspection | |
dc.subject.keywords | thermosonics | |
dc.title | Quantitative Multi-Inspection-Site Comparison of Probability of Detection for Vibrothermography Nondestructive Evaluation Data | |
dc.type | article | |
dc.type.genre | article | |
dspace.entity.type | Publication | |
relation.isAuthorOfPublication | dea444ce-079d-483e-8db1-c33100203381 | |
relation.isAuthorOfPublication | a1ae45d5-fca5-4709-bed9-3dd8efdba54e | |
relation.isOrgUnitOfPublication | 264904d9-9e66-4169-8e11-034e537ddbca |
File
Original bundle
1 - 1 of 1
- Name:
- 2011_MeekerWQ_QuantitativeMultiInspection.pdf
- Size:
- 497.97 KB
- Format:
- Adobe Portable Document Format
- Description: