Optimization and application of ultrasound attenuation estimation algorithms

dc.contributor.advisor Timothy A. Bigelow
dc.contributor.author Labyed, Yassin
dc.contributor.department Department of Electrical and Computer Engineering
dc.date 2018-08-11T16:46:39.000
dc.date.accessioned 2020-06-30T02:34:22Z
dc.date.available 2020-06-30T02:34:22Z
dc.date.copyright Fri Jan 01 00:00:00 UTC 2010
dc.date.embargo 2013-06-05
dc.date.issued 2010-01-01
dc.description.abstract <p>Ultrasound imaging is widely used in clinical settings because of its safe non-ionizing radiation and its low cost. The ultrasound images are generated by performing envelope detection on the backscattered signals. These images show different tissues, organs, and major blood vessels (qualitative information only). In the past three decades however, there has been strong interest in obtaining quantitative information about tissue microstructure by analyzing the backscattered signals rather than using envelope detected data only. The backscattered signals contain information about the size, shape, distribution and mechanical properties of the scatterers within the tissues. These properties can be related to the state of the tissue and may be used to differentiate between healthy and diseased tissue. The tissue microstructure information however, can only be obtained if the total ultrasonic attenuation along the propagation path to the region of interest is accurately compensated. The primary contribution of this thesis is developing two methods for estimating the attenuation along the propagation path. Statistical analysis is performed on each method, and the results are validated using computer simulations and tissue mimicking phantoms. The second contribution is estimating the local ultrasonic attenuation in the cervix of human pregnant patients for the purpose of diagnosing premature delivery. The final contribution is optimizing three common local attenuation estimation algorithms, by using computer simulations and tissue mimicking phantoms.</p>
dc.format.mimetype application/pdf
dc.identifier archive/lib.dr.iastate.edu/etd/11249/
dc.identifier.articleid 2296
dc.identifier.contextkey 2807494
dc.identifier.doi https://doi.org/10.31274/etd-180810-2752
dc.identifier.s3bucket isulib-bepress-aws-west
dc.identifier.submissionpath etd/11249
dc.identifier.uri https://dr.lib.iastate.edu/handle/20.500.12876/25455
dc.language.iso en
dc.source.bitstream archive/lib.dr.iastate.edu/etd/11249/Labyed_iastate_0097E_11443.pdf|||Fri Jan 14 18:45:54 UTC 2022
dc.subject.disciplines Electrical and Computer Engineering
dc.subject.keywords Attenuation
dc.subject.keywords Ultrasound
dc.title Optimization and application of ultrasound attenuation estimation algorithms
dc.type dissertation
dc.type.genre dissertation
dspace.entity.type Publication
relation.isOrgUnitOfPublication a75a044c-d11e-44cd-af4f-dab1d83339ff
thesis.degree.level dissertation
thesis.degree.name Doctor of Philosophy
File
Original bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
Labyed_iastate_0097E_11443.pdf
Size:
2.33 MB
Format:
Adobe Portable Document Format
Description: