Qualifications of duct rumble noise test system

dc.contributor.author Kading, Joshua
dc.contributor.department Mechanical Engineering
dc.date 2020-06-20T02:35:05.000
dc.date.accessioned 2020-06-30T08:14:43Z
dc.date.available 2020-06-30T08:14:43Z
dc.date.copyright Sun Jan 01 00:00:00 UTC 2006
dc.date.issued 2006-01-01
dc.description.abstract <p>"Duct rumble noise is commonly attributed to the poor aerodynamic discharge conditions of fan outlets. Thus far, qualitative descriptors have been used as guidelines for engineers to limit the amount of duct rumble noise. The objective of this study was to create and verify a test facility that would accurately quantify the amount of duct rumble noise that was caused by the change in discharge conditions of a fan and duct system. Valid data will then be used to replace the qualitative descriptor with quantitative predictions. A key design constraint of the testing system is that it can change the sound due to the fan discharge configuration. The test facility was capable of changing between fourteen different discharge conditions. There were four different fan orientations: a fan in front blast condition blowing directly into the duct work, a fan in upblast, with rotation towards the elbow, a fan upblast rotating with the elbow, and a fan upblast rotating against the elbow. Each of these was measured with the fan outlet at different distances away from the duct inlet. The ""optimum"" or frontblast had two distances between the fan and inlet, the rest of the orientations had four distances between the fan and the inlet. The fan was operated at eight operating points on the fan curve to accurately measure the effect of changing configurations on rumble noise. The duct and measurement system was designed to easily measure and verify the sound pressure level effect of the fan discharge conditions. The sound measurements were taken at one-third octave bands between 16 and 300 Hz. The narrow band analysis was taken up to 800 Hz. The measurements were taken in an acoustically isolated room at nine locations in the room and seven locations in the ductwork. The accuracy of the measurement was within ± 1dB, which was far less than the 3 to 11 dB variations that are caused by the fan configuration."</p>
dc.format.mimetype application/pdf
dc.identifier archive/lib.dr.iastate.edu/rtd/19307/
dc.identifier.articleid 20306
dc.identifier.contextkey 18174293
dc.identifier.doi https://doi.org/10.31274/rtd-20200618-19
dc.identifier.s3bucket isulib-bepress-aws-west
dc.identifier.submissionpath rtd/19307
dc.identifier.uri https://dr.lib.iastate.edu/handle/20.500.12876/73303
dc.language.iso en
dc.source.bitstream archive/lib.dr.iastate.edu/rtd/19307/Kading_ISU_2006_K335.pdf|||Fri Jan 14 21:54:37 UTC 2022
dc.subject.keywords Mechanical engineering
dc.title Qualifications of duct rumble noise test system
dc.type article
dc.type.genre thesis
dspace.entity.type Publication
relation.isOrgUnitOfPublication 6d38ab0f-8cc2-4ad3-90b1-67a60c5a6f59
thesis.degree.discipline Mechanical Engineering
thesis.degree.level thesis
thesis.degree.name Master of Science
File
Original bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
Kading_ISU_2006_K335.pdf
Size:
12.76 MB
Format:
Adobe Portable Document Format
Description: