A new thermo-time domain reflectometry approach to quantify soil ice content at temperatures near the freezing point

Thumbnail Image
Date
2020-03-26
Authors
Kojima, Yuki
Nakano, Yuta
Kato, Chihiro
Noborio, Kosuke
Kamiya, Kohji
Horton, Robert
Major Professor
Advisor
Committee Member
Journal Title
Journal ISSN
Volume Title
Publisher
Authors
Person
Horton, Robert
Distinguished Professor
Research Projects
Organizational Units
Organizational Unit
Journal Issue
Is Version Of
Versions
Series
Department
Agronomy
Abstract

Soil ice content (θi) is an important property for many studies associated with cold regions. In situ quantification of θi with thermo-time domain reflectometry (TDR) at temperatures near the freezing point has been difficult. The objective of this study is to propose and test a new thermo-TDR approach to determine θi. First, the liquid water content (θl) of a partially frozen soil is determined from a TDR waveform. Next, a pulse of heat is applied through the thermo-TDR sensor to melt the ice in the partially frozen soil. Then, a second TDR waveform is obtained after melting to determine the θl, which is equivalent to the total water content (θt ) of the partially frozen soil. Finally, θi is calculated as the difference between θt and θl. The performance of the new approach was evaluated in sand and loam soils at a variety of θ t values. The new approach estimated θt , θl, and θi accurately. The root mean square errors (RMSE) of estimation were 0.013, 0.020, and 0.023 m3 m−3 for sand, and 0.041, 0.026, and 0.031 m3 m−3 for loam. These RMSE values are smaller than those reported in earlier thermo-TDR studies. Repeating the thermo-TDR measurements at the same location on the same soil sample caused decreased accuracy of estimated values, because of radial water transfer away from the heater tube of the thermo-TDR sensor. Further research is needed to determine if it is possible to obtain accurate repeated measurements. The use of a dielectric mixing model to convert the soil apparent dielectric constant to θl improved the accuracy of this approach. In our investigation, application of a small heat intensity until the partially frozen soil temperature became larger than about 1°C was favorable. The new method was shown to be suitable for estimating ice contents in soil at temperatures between 0°C and -2°C, and it could be combined with the volumetric heat capacity or thermal conductivity thermo-TDR based methods, which measured ice content at colder temperatures. Thus, the thermo-TDR technique could measure θi at all temperatures.

Comments

This is a manuscript of an article published as Kojima, Yuki, Yuta Nakano, Chihiro Kato, Kosuke Noborio, Kohji Kamiya, and Robert Horton. "A new thermo-time domain reflectometry approach to quantify soil ice content at temperatures near the freezing point." Cold Regions Science and Technology (2020): 103060. doi: 10.1016/j.coldregions.2020.103060.

Description
Keywords
Citation
DOI
Copyright
Wed Jan 01 00:00:00 UTC 2020
Collections