Noncontact Measurement of Applied Static Torque

Date
1996
Authors
Zinke, O.
Schmidt, W.
Major Professor
Advisor
Committee Member
Journal Title
Journal ISSN
Volume Title
Publisher
Altmetrics
Authors
Research Projects
Organizational Units
Journal Issue
Series
Department
Abstract

Schmidt and Zinke [1,2] have shown that the ac magnetic bridge can be used to make noncontact measurements of changes of strain in an axially loaded bar. Therefore, there seemed to be no a priori reason why the bridge could not be used to make noncontact measurements of shear stress produced by static torque. The results of such measurements are described here. A 2.54-cm cold-rolled steel bar was placed in a fixture and subjected to various applied torques. The measurements produced an initial transient signal followed by a changed static signal. The transient signal, which lasts the order of 6–8 seconds, seemed to be proportional to the rate of change of the application of torque although no quantitative measurements were made to prove this. The static signal, which was measured 30 seconds after the torque was applied, was proportional to the torque over the range of torques from 4 to 57 newton meters. If transient signals had been produced in the original linear stress tests [1,2], they would not have been noticed because of the technique of obtaining the data in those experiments.

Comments
Description
Keywords
Citation
DOI