Strength Characteristics of Swine Injection Devices

Thumbnail Image
Date
1997
Authors
Hoff, Steven
Major Professor
Advisor
Committee Member
Journal Title
Journal ISSN
Volume Title
Publisher
Authors
Person
Hoff, Steven
Professor Emeritus
Research Projects
Organizational Units
Journal Issue
Is Version Of
Versions
Series
Department
Abstract

Various needle gauges, lengths, and hub material was tested under static loading conditions. Significant differences exist in the needle industry in terms of strength and failure rate. Needle breakage was found to occur only when a bent needle was straightened and then reused. Manufacturing differences were found especially in the bond that joins the needle/hub assembly resulting in significant differences in failure rate

Comments
Description
Keywords
Citation
DOI
Source
Keywords
Copyright
Wed Jan 01 00:00:00 UTC 1997
Collections