Forces on Temperature Cables in a Model Bin Under Restrained Conditions
Date
Authors
Major Professor
Advisor
Committee Member
Journal Title
Journal ISSN
Volume Title
Publisher
Abstract
Temperature cables restrained from lateral movement, were measured as a function of grain height, cable location and surface coating. For the restrained conditions, the cable forces were one to nine times those previously measured for unrestrained cables. The large load increase on the restrained cables is believed to be caused by the flow profile which existed at each of the three different cable locations. The flow profile at the center cable is predominantly vertical and the forces in the restrained condition resembled those in the unrestrained condition. For the two outer cable locations, both vertical and lateral force components exist because of the nature of the discharging grain at these two different locations. For the restrained condition, the largest forces occurred on the cable located at the middle position. For the unrestrained condition, the largest forces occurred on the cable located at the wall position. Surface coatings on the cable had an effect on the magnitude of the forces. Forces on vinyl coated cables were significantly larger than either the nylon or HDLE polyethylene coated cables in the restrained condition.
Series Number
Journal Issue
Is Version Of
Versions
Series
Academic or Administrative Unit
Type
Comments
This article is from Transactions of the ASAE 34, no. 5 (1991): 2187–2192.