A Novel Non-Contact Ultrasonic System for Liquid Level Measurement in Moving Metallic Containers

Thumbnail Image
Date
1998
Authors
Dixon, S.
Edwards, C.
Palmer, S.
Major Professor
Advisor
Committee Member
Journal Title
Journal ISSN
Volume Title
Publisher
Abstract

The majority of conventional liquid level monitors in industry operate using a gamma-ray absorption technique. Gamma-rays with energies utilised in these machines are strongly absorbed by water/liquids. In a γ -ray measurement a collimated beam is momentarily exposed to the container that is to be measured, with some of the beam below and some above the nominal liquid level. The γ-rays are detected using a scintillation tube after passing through the container and its contents. Thus if more of the γ -ray beam is absorbed by a higher liquid level, the counts drop, and vice-versa. The type of machine is in the main a pass/fail monitor — that is it passes a can if the liquid level is above a predetermined height, and rejects it if it is not. There are several problems associated with the use of γ -ray based systems, most notably environmental considerations, the fact they are potentially hazardous and subject to strict legislation.