Minimum Ventilation Requirement and Associated Energy Cost for Aerial Ammonia Control in Broiler Houses
dc.contributor.author | Xin, Hongwei | |
dc.contributor.author | Berry, Ivan | |
dc.contributor.author | Tabler, G. | |
dc.contributor.department | Department of Agricultural and Biosystems Engineering (ENG) | |
dc.date | 2018-02-13T04:22:41.000 | |
dc.date.accessioned | 2020-06-29T22:37:45Z | |
dc.date.available | 2020-06-29T22:37:45Z | |
dc.date.copyright | Mon Jan 01 00:00:00 UTC 1996 | |
dc.date.embargo | 2012-12-14 | |
dc.date.issued | 1996 | |
dc.description.abstract | <p>Minimum ventilation rate (MVR) and bird performance of four commercial-scale broiler houses were monitored for 16 consecutive growouts. A complete house clean-out was conducted after the 7th growout and again after the 13th growout. Between the clean-outs, only caked litter was removed, and new bedding was added to the old litter.</p> | |
dc.description.comments | <p>Journal Paper No. J-16448 of the Iowa Agriculture and Home Economics Experiment Station, Ames, Iowa. Project 3311. Mention of product or company names does not imply endorsement of the product by the authors or their organizations, nor exclusion of any other products that may be suitable.</p> <p>This article is from <em><a href="http://elibrary.asabe.org/abstract.asp?aid=27547&t=3&dabs=Y&redir=&redirType=" target="_blank">Transactions of the ASAE</a> </em>39, no. 2 (1996): 645–648.</p> | |
dc.format.mimetype | application/pdf | |
dc.identifier | archive/lib.dr.iastate.edu/abe_eng_pubs/182/ | |
dc.identifier.articleid | 1186 | |
dc.identifier.contextkey | 3538788 | |
dc.identifier.s3bucket | isulib-bepress-aws-west | |
dc.identifier.submissionpath | abe_eng_pubs/182 | |
dc.identifier.uri | https://dr.lib.iastate.edu/handle/20.500.12876/921 | |
dc.language.iso | en | |
dc.source.bitstream | archive/lib.dr.iastate.edu/abe_eng_pubs/182/X_in_1996_MinimumVentilationRequirement.pdf|||Fri Jan 14 21:38:15 UTC 2022 | |
dc.subject.disciplines | Agriculture | |
dc.subject.disciplines | Bioresource and Agricultural Engineering | |
dc.subject.keywords | Aerial ammonia | |
dc.subject.keywords | Broiler | |
dc.subject.keywords | Energy | |
dc.subject.keywords | House clean-out | |
dc.subject.keywords | Minimum ventilation | |
dc.title | Minimum Ventilation Requirement and Associated Energy Cost for Aerial Ammonia Control in Broiler Houses | |
dc.type | article | |
dc.type.genre | article | |
dspace.entity.type | Publication | |
relation.isAuthorOfPublication | 36e0a8ce-fa2e-4df4-9f67-8d1717122650 | |
relation.isOrgUnitOfPublication | 8eb24241-0d92-4baf-ae75-08f716d30801 |
File
Original bundle
1 - 1 of 1
No Thumbnail Available
- Name:
- X_in_1996_MinimumVentilationRequirement.pdf
- Size:
- 813.75 KB
- Format:
- Adobe Portable Document Format
- Description: