Airflow Pattern Similarity Criteria for Ceiling Slot-ventilated Agricultural Enclosures under Isothermal Conditions

dc.contributor.author Yu, Hsin
dc.contributor.author Hoff, Steven
dc.contributor.department Department of Agricultural and Biosystems Engineering (ENG)
dc.date 2018-02-13T10:12:21.000
dc.date.accessioned 2020-06-29T22:39:11Z
dc.date.available 2020-06-29T22:39:11Z
dc.date.copyright Fri Jan 01 00:00:00 UTC 1999
dc.date.embargo 2013-04-30
dc.date.issued 1999
dc.description.abstract <p>The use of a scaled model can be an effective technique to predict ventilation performance of full-scale prototypes. Many criteria have been proposed to predict the behavior of airflow in a scale model and a prototype. Because of inconsistent results of proposed similarity criteria, more validation work is needed to clarify the conflicts. Experiments to study airflow similarity in ceiling slot-ventilated agricultural enclosures using different similarity criteria were conducted on two scale models. The studies focused on the Reynolds number (Re) and inlet jet momentum ratio (Rm) as the similitude criteria for isothermal airflow. The experimental results offer better agreement using Rm as opposed to Re as the similitude criterion for isothermal airflow pattern control.</p>
dc.description.comments <p>This article is from <em>Transactions of the ASAE </em>42, no. 2 (1999): <a href="http://elibrary.asabe.org/abstract.asp?aid=13378&t=3&dabs=Y&redir=&redirType=" target="_blank">459–469</a>.</p>
dc.format.mimetype application/pdf
dc.identifier archive/lib.dr.iastate.edu/abe_eng_pubs/360/
dc.identifier.articleid 1625
dc.identifier.contextkey 4089303
dc.identifier.s3bucket isulib-bepress-aws-west
dc.identifier.submissionpath abe_eng_pubs/360
dc.identifier.uri https://dr.lib.iastate.edu/handle/20.500.12876/1118
dc.language.iso en
dc.source.bitstream archive/lib.dr.iastate.edu/abe_eng_pubs/360/1999_YuH_AirflowPatternSimilarity.pdf|||Fri Jan 14 23:47:14 UTC 2022
dc.subject.disciplines Agriculture
dc.subject.disciplines Bioresource and Agricultural Engineering
dc.subject.keywords Airflow
dc.subject.keywords Slot-ventilated
dc.subject.keywords Similitude
dc.subject.keywords Ventilation
dc.title Airflow Pattern Similarity Criteria for Ceiling Slot-ventilated Agricultural Enclosures under Isothermal Conditions
dc.type article
dc.type.genre article
dspace.entity.type Publication
relation.isAuthorOfPublication 98b46d48-66a2-4458-9b42-8c4aa050664d
relation.isOrgUnitOfPublication 8eb24241-0d92-4baf-ae75-08f716d30801
File
Original bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
1999_YuH_AirflowPatternSimilarity.pdf
Size:
2.08 MB
Format:
Adobe Portable Document Format
Description:
Collections