Use of CO 2 Concentrations or CO 2 Balance to Estimate Ventilation Rate of Modern Commercial Broiler Houses

dc.contributor.author Gates, Richard
dc.contributor.author Li, Hong
dc.contributor.author Xin, Hongwei
dc.contributor.author Burns, Robert
dc.contributor.author Moody, Lara
dc.contributor.author Hoff, Steven
dc.contributor.author Overhults, Douglas
dc.contributor.author Earnest, John
dc.contributor.department Department of Agricultural and Biosystems Engineering (ENG)
dc.date 2018-02-13T04:27:19.000
dc.date.accessioned 2020-06-29T22:32:17Z
dc.date.available 2020-06-29T22:32:17Z
dc.date.copyright Sun Jan 01 00:00:00 UTC 2006
dc.date.embargo 2012-12-14
dc.date.issued 2006-07-01
dc.description.abstract <p>Ventilation rate (VR) is one of the two key elements for quantifying aerial emissions from animal production facilities. Direct measurement of building VR can be challenging and impractical under certain circumstances, e.g., naturally ventilated animal housing. This study delineates VR of broiler houses with build-up litter as estimated via CO2 balance or building CO2 concentration. The indirectly derived VR compared favorably with the directly measured VR. Specifically, integration time of 30 min or longer leads to non-significant differences in VR between the indirect and the direct methods (P>0.2). Omission of CO2 generation by the litter from total house CO2 production results in an overall 7% underestimation of the building VR. The indirect method provides a possible, viable alternative for quantifying VR of naturally ventilated broiler confinement.</p>
dc.description.comments <p>This is an ASAE Meeting Presentation, Paper No. <a href="http://elibrary.asabe.org/abstract.asp?aid=21150&t=3&dabs=Y&redir=&redirType=" target="_blank">064156</a>.</p>
dc.identifier archive/lib.dr.iastate.edu/abe_eng_conf/193/
dc.identifier.articleid 1202
dc.identifier.contextkey 3538943
dc.identifier.s3bucket isulib-bepress-aws-west
dc.identifier.submissionpath abe_eng_conf/193
dc.identifier.uri https://dr.lib.iastate.edu/handle/20.500.12876/198
dc.language.iso en
dc.source.bitstream archive/lib.dr.iastate.edu/abe_eng_conf/193/Xin_2006_UseCO2Concentrations.pdf|||Fri Jan 14 21:54:15 UTC 2022
dc.subject.disciplines Bioresource and Agricultural Engineering
dc.subject.keywords Air emissions
dc.subject.keywords metabolic rate
dc.subject.keywords indirect animal calorimetry
dc.subject.keywords Fan Assessment Numeration System (FANS)
dc.title Use of CO 2 Concentrations or CO 2 Balance to Estimate Ventilation Rate of Modern Commercial Broiler Houses
dc.type article
dc.type.genre conference
dspace.entity.type Publication
relation.isAuthorOfPublication a61fa792-56f2-4397-8a9c-8cbde8d5c3f1
relation.isAuthorOfPublication 36e0a8ce-fa2e-4df4-9f67-8d1717122650
relation.isAuthorOfPublication 98b46d48-66a2-4458-9b42-8c4aa050664d
relation.isOrgUnitOfPublication 8eb24241-0d92-4baf-ae75-08f716d30801
File
Original bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
Xin_2006_UseCO2Concentrations.pdf
Size:
2.45 MB
Format:
Adobe Portable Document Format
Description: