Fan Assessment Numeration System (FANS) Design and Calibration Specifications
dc.contributor.author | Gates, Richard | |
dc.contributor.author | Casey, Kenneth | |
dc.contributor.author | Wheeler, Eileen | |
dc.contributor.author | Xin, Hongwei | |
dc.contributor.author | Simmons, John | |
dc.contributor.department | Agricultural and Biosystems Engineering | |
dc.date | 2018-02-13T04:18:46.000 | |
dc.date.accessioned | 2020-06-29T22:37:38Z | |
dc.date.available | 2020-06-29T22:37:38Z | |
dc.date.copyright | Thu Jan 01 00:00:00 UTC 2004 | |
dc.date.embargo | 2012-12-13 | |
dc.date.issued | 2004-01-01 | |
dc.description.abstract | <p>A device for in-situ fan airflow measurement, known as the Fan Assessment Numeration System (FANS) device, previously developed and constructed at the USDA-ARS Southern Poultry Research Laboratory, was refined at University of Kentucky as part of a project for quantifying building emissions from mechanically ventilated poultry and livestock facilities. The FANS incorporates an array of five propeller anemometers to perform a real-time traverse of the airflow entering fans of up to 137 cm (54 in.) diameter. Details of the updated design, including hardware, software, and calibration methodology are presented. An error analysis of the flow rate, and calibration results from ten FANS units, is provided. Sufficient details of fabrication and calibration are presented so that interested readers can replicate a FANS for their use. Full design details are available at www.bae.uky.edu/IFAFS/FANS.htm.</p> | |
dc.description.comments | <p>This article is from <em><a href="http://elibrary.asabe.org/abstract.asp?aid=17613&t=3&dabs=Y&redir=&redirType=" target="_blank">Transactions of the ASAE</a> </em>47, no. 5 (2004): 1709–1715.</p> | |
dc.format.mimetype | application/pdf | |
dc.identifier | archive/lib.dr.iastate.edu/abe_eng_pubs/168/ | |
dc.identifier.articleid | 1173 | |
dc.identifier.contextkey | 3536227 | |
dc.identifier.s3bucket | isulib-bepress-aws-west | |
dc.identifier.submissionpath | abe_eng_pubs/168 | |
dc.identifier.uri | https://dr.lib.iastate.edu/handle/20.500.12876/905 | |
dc.language.iso | en | |
dc.source.bitstream | archive/lib.dr.iastate.edu/abe_eng_pubs/168/Xin_2004_FanAssessmentNumeration.pdf|||Fri Jan 14 21:06:04 UTC 2022 | |
dc.subject.disciplines | Agriculture | |
dc.subject.disciplines | Bioresource and Agricultural Engineering | |
dc.subject.keywords | Controlled environment | |
dc.subject.keywords | Emissions | |
dc.subject.keywords | Instrumentation | |
dc.subject.keywords | Livestock housing | |
dc.subject.keywords | Poultry | |
dc.subject.keywords | Ventilation | |
dc.title | Fan Assessment Numeration System (FANS) Design and Calibration Specifications | |
dc.type | article | |
dc.type.genre | article | |
dspace.entity.type | Publication | |
relation.isAuthorOfPublication | a61fa792-56f2-4397-8a9c-8cbde8d5c3f1 | |
relation.isAuthorOfPublication | 36e0a8ce-fa2e-4df4-9f67-8d1717122650 | |
relation.isOrgUnitOfPublication | 8eb24241-0d92-4baf-ae75-08f716d30801 |
File
Original bundle
1 - 1 of 1
No Thumbnail Available
- Name:
- Xin_2004_FanAssessmentNumeration.pdf
- Size:
- 483.3 KB
- Format:
- Adobe Portable Document Format
- Description: