A Portable System for Continuous Ammonia Measurement in the Field
dc.contributor.author | Gates, Richard | |
dc.contributor.author | Tanaka, Akihiro | |
dc.contributor.author | Xin, Hongwei | |
dc.contributor.author | Wheeler, Eileen | |
dc.contributor.author | Casey, Ken | |
dc.contributor.author | Wang, Tong | |
dc.contributor.author | Heber, Albert | |
dc.contributor.author | Ni, Ji-Qin | |
dc.contributor.author | Lim, Teng | |
dc.contributor.department | Department of Agricultural and Biosystems Engineering (ENG) | |
dc.date | 2018-02-13T04:09:06.000 | |
dc.date.accessioned | 2020-06-29T22:31:33Z | |
dc.date.available | 2020-06-29T22:31:33Z | |
dc.date.copyright | Tue Jan 01 00:00:00 UTC 2002 | |
dc.date.embargo | 2012-12-13 | |
dc.date.issued | 2002-07-01 | |
dc.description.abstract | <p>A portable and relatively low-cost monitoring unit (PMU) for continuous measurement of ammonia and carbon dioxide in CAFO (poultry in particular) applications has been developed and partially compared with an EPA-approved measurement method. The PMU utilizes sampling and purging cycles to overcome the sensor saturation characteristic of electro-chemical NH3 sensors. Preliminary comparative results show that performance of the PMU is quite comparable to the sophisticated, highercost, and less portable mobile lab method. For the range of ammonia level typical of commercial poultry buildings, the PMU is expected to produce emission rate data of reasonable quality when combined with properly measured or determined building ventilation rate.</p> | |
dc.description.comments | <p>This is an ASAE Meeting Presentation, Paper No. <a href="http://elibrary.asabe.org/abstract.asp?aid=21755&t=3&dabs=Y&redir=&redirType=" target="_blank">024168</a>.</p> | |
dc.identifier | archive/lib.dr.iastate.edu/abe_eng_conf/117/ | |
dc.identifier.articleid | 1119 | |
dc.identifier.contextkey | 3534679 | |
dc.identifier.s3bucket | isulib-bepress-aws-west | |
dc.identifier.submissionpath | abe_eng_conf/117 | |
dc.identifier.uri | https://dr.lib.iastate.edu/handle/20.500.12876/114 | |
dc.language.iso | en | |
dc.source.bitstream | archive/lib.dr.iastate.edu/abe_eng_conf/117/Xin_2002_PortableSystemContinuous.pdf|||Fri Jan 14 18:55:52 UTC 2022 | |
dc.subject.disciplines | Bioresource and Agricultural Engineering | |
dc.subject.disciplines | Food Science | |
dc.subject.disciplines | Human and Clinical Nutrition | |
dc.subject.keywords | Ammonia Emissions | |
dc.subject.keywords | Concentrated Animal Feeding Operations (CAFOs) | |
dc.subject.keywords | Air Quality | |
dc.title | A Portable System for Continuous Ammonia Measurement in the Field | |
dc.type | article | |
dc.type.genre | conference | |
dspace.entity.type | Publication | |
relation.isAuthorOfPublication | a61fa792-56f2-4397-8a9c-8cbde8d5c3f1 | |
relation.isAuthorOfPublication | 36e0a8ce-fa2e-4df4-9f67-8d1717122650 | |
relation.isAuthorOfPublication | 8abd4880-ae81-4395-8ebb-00addaf5f60a | |
relation.isOrgUnitOfPublication | 8eb24241-0d92-4baf-ae75-08f716d30801 |
File
Original bundle
1 - 1 of 1
No Thumbnail Available
- Name:
- Xin_2002_PortableSystemContinuous.pdf
- Size:
- 598.29 KB
- Format:
- Adobe Portable Document Format
- Description: