A Portable System for Continuous Ammonia Measurement in the Field

dc.contributor.author Gates, Richard
dc.contributor.author Tanaka, Akihiro
dc.contributor.author Xin, Hongwei
dc.contributor.author Wheeler, Eileen
dc.contributor.author Casey, Ken
dc.contributor.author Wang, Tong
dc.contributor.author Heber, Albert
dc.contributor.author Ni, Ji-Qin
dc.contributor.author Lim, Teng
dc.contributor.department Department of Agricultural and Biosystems Engineering (ENG)
dc.date 2018-02-13T04:09:06.000
dc.date.accessioned 2020-06-29T22:31:33Z
dc.date.available 2020-06-29T22:31:33Z
dc.date.copyright Tue Jan 01 00:00:00 UTC 2002
dc.date.embargo 2012-12-13
dc.date.issued 2002-07-01
dc.description.abstract <p>A portable and relatively low-cost monitoring unit (PMU) for continuous measurement of ammonia and carbon dioxide in CAFO (poultry in particular) applications has been developed and partially compared with an EPA-approved measurement method. The PMU utilizes sampling and purging cycles to overcome the sensor saturation characteristic of electro-chemical NH3 sensors. Preliminary comparative results show that performance of the PMU is quite comparable to the sophisticated, highercost, and less portable mobile lab method. For the range of ammonia level typical of commercial poultry buildings, the PMU is expected to produce emission rate data of reasonable quality when combined with properly measured or determined building ventilation rate.</p>
dc.description.comments <p>This is an ASAE Meeting Presentation, Paper No. <a href="http://elibrary.asabe.org/abstract.asp?aid=21755&t=3&dabs=Y&redir=&redirType=" target="_blank">024168</a>.</p>
dc.identifier archive/lib.dr.iastate.edu/abe_eng_conf/117/
dc.identifier.articleid 1119
dc.identifier.contextkey 3534679
dc.identifier.s3bucket isulib-bepress-aws-west
dc.identifier.submissionpath abe_eng_conf/117
dc.identifier.uri https://dr.lib.iastate.edu/handle/20.500.12876/114
dc.language.iso en
dc.source.bitstream archive/lib.dr.iastate.edu/abe_eng_conf/117/Xin_2002_PortableSystemContinuous.pdf|||Fri Jan 14 18:55:52 UTC 2022
dc.subject.disciplines Bioresource and Agricultural Engineering
dc.subject.disciplines Food Science
dc.subject.disciplines Human and Clinical Nutrition
dc.subject.keywords Ammonia Emissions
dc.subject.keywords Concentrated Animal Feeding Operations (CAFOs)
dc.subject.keywords Air Quality
dc.title A Portable System for Continuous Ammonia Measurement in the Field
dc.type article
dc.type.genre conference
dspace.entity.type Publication
relation.isAuthorOfPublication a61fa792-56f2-4397-8a9c-8cbde8d5c3f1
relation.isAuthorOfPublication 36e0a8ce-fa2e-4df4-9f67-8d1717122650
relation.isAuthorOfPublication 8abd4880-ae81-4395-8ebb-00addaf5f60a
relation.isOrgUnitOfPublication 8eb24241-0d92-4baf-ae75-08f716d30801
File
Original bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
Xin_2002_PortableSystemContinuous.pdf
Size:
598.29 KB
Format:
Adobe Portable Document Format
Description: