Ammonia Distribution in a Pit-ventilated Confinement Building: One-half Scale Model Study
Date
Authors
Major Professor
Advisor
Committee Member
Journal Title
Journal ISSN
Volume Title
Publisher
Abstract
A one-half scale model of a pit-ventilated swine confinement barn was used to study the effects of building design and management factors on the distribution of ammonia in the airspace. Two slat orientations, two manure depths (full and empty), and two ventilation rates, representative of winter conditions, were compared. As expected, the ventilation rate was a major factor in determining average levels of ammonia in the airspace. Manure depth significantly affected ammonia levels and gas distribution in the airspace above and below the slatted floor. Large stagnant regions were observed in the manure pit head-space for a nearly empty manure pit. Floor slat orientation did not appear to significantly affect average ammonia levels or the distribution of ammonia in the airspace, although some effects may have been present at the higher ventilation rate tested.
Series Number
Journal Issue
Is Version Of
Versions
Series
Academic or Administrative Unit
Type
Comments
This article is from Transactions of the ASAE 41, no. 6 (1998): 1817–1827.