Dilute-and-shoot approach combined with in-situ formed metal-containing ionic liquids for extraction of benzophenone and related compounds from açaí-based food products

dc.contributor.author Silva Nascimento, Luis Eduardo
dc.contributor.author Da Silva Oliveira, Wellington
dc.contributor.author Gody Teixeira, Helena
dc.contributor.author Anderson, Jared
dc.contributor.department Department of Chemistry
dc.date.accessioned 2024-02-01T16:28:38Z
dc.date.available 2024-02-01T16:28:38Z
dc.date.issued 2024-01-27
dc.description.abstract For the first time, benzophenone and related compounds were investigated in açaí-based food products. An extraction method based on the dilute-and-shoot approach, combined with the use of in-situ formed metal-containing ionic liquids (MCILs) followed by high-performance liquid chromatography, was developed and validated. A nickel and cobalt-based MCIL, in addition to the ratio of MCIL to lithium bis[(trifluoromethyl)sulfonyl]imide salt ([Li+][NTf2−]) for the ensuing metathesis reaction, were optimized. Parameters of the in-situ formed MCIL step, namely, the amount of MCIL, centrifugation time, and dilution step, were analyzed using a multivariate optimization approach, including central composite rotatable design and Derringer and Suich's tool. Optimum extraction performance was achieved using 50.98 mg of nickel-based MCIL and a MCIL to ([Li+][NTf2−]) ratio of 1:3 (m/m), a centrifuge time of 22 mins, and 10.53 mL of water for the dilution step. This condition was used to perform analytical validation, which yielded satisfactory results with R2 ≥ 0.995, limits of detection (LOD) ranging from 0.0025 to 0.5 mg kg−1, and limits of quantification (LOQ) between 0.008 and 1.5 mg kg−1. The recovery rate ranged from 87% to 107% and precision values (as percent relative standard deviation) were equal or lower than 13%. The validated method was applied to 25 samples of açaí-based food products purchased from Brazil and the United States. None of the samples showed analyte concentration levels above the LOD. The method's suitability was demonstrated for future monitoring of complex samples, such as foodstuffs.
dc.description.comments This is a pre-proof of the article Published as NASCIMENTO, Luis Eduardo SILVA, Wellington DA SILVA OLIVEIRA, Nabeel MUJTABA ABBASI, Helena TEIXEIRA GODOY, and Jared L. ANDERSON. "Dilute-and-shoot approach combined with in-situ formed metal-containing ionic liquids for extraction of benzophenone and related compounds from açaí-based food products." Journal of Chromatography A (2024): 464686. doi: https://doi.org/10.1016/j.chroma.2024.464686. © 2024 Elsevier B.V. CC BY-NC-ND.
dc.identifier.uri https://dr.lib.iastate.edu/handle/20.500.12876/YvkA09Jz
dc.language.iso en
dc.publisher Elsevier B.V.
dc.source.uri https://doi.org/10.1016/j.chroma.2024.464686 *
dc.subject.disciplines DegreeDisciplines::Physical Sciences and Mathematics::Chemistry::Analytical Chemistry
dc.subject.keywords Food analysis
dc.subject.keywords food contaminant
dc.subject.keywords food-packaging contaminants
dc.subject.keywords UV-filters
dc.subject.keywords sample preparation
dc.title Dilute-and-shoot approach combined with in-situ formed metal-containing ionic liquids for extraction of benzophenone and related compounds from açaí-based food products
dc.type article
dspace.entity.type Publication
relation.isAuthorOfPublication 9618e7bf-b6eb-4753-affc-fca4bcc405cb
relation.isOrgUnitOfPublication 42864f6e-7a3d-4be3-8b5a-0ae3c3830a11
File
Collections