Quality Assured Measurements of Animal Building Emissions: Odor Concentrations

dc.contributor.author Jacobson, Larry
dc.contributor.author Hetchler, Brian
dc.contributor.author Schmidt, David
dc.contributor.author Nicolai, Richard
dc.contributor.author Hoff, Steven
dc.contributor.author Heber, Albert
dc.contributor.author Ni, Ji-Quin
dc.contributor.author Koziel, Jacek
dc.contributor.author Zhang, Yuanhui
dc.contributor.author Beasley, David
dc.contributor.author Parker, David
dc.contributor.department Department of Agricultural and Biosystems Engineering (ENG)
dc.date 2018-04-12T22:32:11.000
dc.date.accessioned 2020-06-29T22:43:46Z
dc.date.available 2020-06-29T22:43:46Z
dc.date.copyright Tue Jan 01 00:00:00 UTC 2008
dc.date.issued 2008-01-01
dc.description.abstract <p>Standard protocols for sampling and measuring odor emissions from livestock buildings are needed to guide scientists, consultants, regulators, and policy-makers. A federally funded, multistate project has conducted field studies in six states to measure emissions of odor, coarse particulate matter (PM10), total suspended particulates, hydrogen sulfide, ammonia, and carbon dioxide from swine and poultry production buildings. The focus of this paper is on the intermittent measurement of odor concentrations at nearly identical pairs of buildings in each state and on protocols to minimize variations in these measurements. Air was collected from pig and poultry barns in small (10 L) Tedlar bags through a gas sampling system located in an instrument trailer housing gas and dust analyzers. The samples were analyzed within 30 hr by a dynamic dilution forced-choice olfactometer (a dilution apparatus). The olfactometers (AC’SCENT International Olfactometer, St. Croix Sensory, Inc.) used by all participating laboratories meet the olfactometry standards (American Society for Testing and Materials and European Committee for Standardization [CEN]) in the United States and Europe. Trained panelists (four to eight) at each laboratory measured odor concentrations (dilution to thresholds [DT]) from the bag samples. Odor emissions were calculated by multiplying odor concentration differences between inlet and outlet air by standardized (20 °C and 1 atm) building airflow rates.</p>
dc.description.comments <p>This is an Accepted Manuscript of an article published by Taylor & Francis as Jacobson, Larry D., Brian P. Hetchler, David R. Schmidt, Richard E. Nicolai, Albert J. Heber, Ji-Qin Ni, Steven J. Hoff et al. "Quality assured measurements of animal building emissions: Odor concentrations." <em>Journal of the Air & Waste Management Association</em> 58, no. 6 (2008): 806-811.. Available online DOI: <a href="http://dx.doi.org/10.3155/1047-3289.58.6.806" target="_blank">10.3155/1047-3289.58.6.806</a>. Posted with permission.</p>
dc.format.mimetype application/pdf
dc.identifier archive/lib.dr.iastate.edu/abe_eng_pubs/929/
dc.identifier.articleid 2206
dc.identifier.contextkey 11951509
dc.identifier.s3bucket isulib-bepress-aws-west
dc.identifier.submissionpath abe_eng_pubs/929
dc.identifier.uri https://dr.lib.iastate.edu/handle/20.500.12876/1745
dc.language.iso en
dc.source.bitstream archive/lib.dr.iastate.edu/abe_eng_pubs/929/2008_Koziel_QualityAssured.pdf|||Sat Jan 15 02:30:48 UTC 2022
dc.source.uri 10.3155/1047-3289.58.6.806
dc.subject.disciplines Agriculture
dc.subject.disciplines Animal Sciences
dc.subject.disciplines Bioresource and Agricultural Engineering
dc.subject.disciplines Environmental Sciences
dc.subject.keywords air quality
dc.subject.keywords detection threshold
dc.subject.keywords emissions
dc.subject.keywords emission factors
dc.subject.keywords livestock 50 housing
dc.subject.keywords nuisance
dc.subject.keywords odor
dc.subject.keywords olfactometry
dc.subject.keywords quality assurance
dc.subject.keywords sampling
dc.title Quality Assured Measurements of Animal Building Emissions: Odor Concentrations
dc.type article
dc.type.genre article
dspace.entity.type Publication
relation.isAuthorOfPublication 98b46d48-66a2-4458-9b42-8c4aa050664d
relation.isAuthorOfPublication 76fc5589-51f8-4f3c-885c-e25d8037d641
relation.isOrgUnitOfPublication 8eb24241-0d92-4baf-ae75-08f716d30801
File
Original bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
2008_Koziel_QualityAssured.pdf
Size:
112.51 KB
Format:
Adobe Portable Document Format
Description:
Collections