Evaluation of High Spatial Resolution Imaging of Magnetic Stray Fields for Early Damage Detection

Date
2016-01-01
Authors
Stegemann, Robert
Sonntag, Nadja
Cabeza, Sandra
Lyamkin, Viktor
Pelkner, Matthias
Bruno, Giovanni
Skrotzki, Birgit
Kreutzbruck, Marc
Journal Title
Journal ISSN
Volume Title
Publisher
Source URI
Altmetrics
Authors
Research Projects
Organizational Units
Journal Issue
Series
Abstract

Metal magnetic memory (MMM) technique with associated ISO 24497-1:3 [1] is gaining considerable interest in the magnetic NDT community. In contrast to traditional Magnetic Flux Leakage (MFL) testing, the inspection objects are not intentionally magnetized by an external magnetic field [1,2]. Due to the physical coupling between mechanical stress and magnetization of ferromagnetic materials [3], it is assumed that the distribution of the residual MFL correspond to the internal stress of the specimen [2,4], or in the most general sense, to a degradation of the material [1,2].

Usually, MMM measurements are performed by relatively bulky magnetic inspection sensors [2]. The evaluation of local magnetic field distribution is limited thereby. High precision GMR (Giant Magneto Resistance) measurements in the micrometer regime can provide a higher degree of information due to better spatial resolution [5].

We present a concise summary of studies on the correlation of magnetic structure and microstructure of steels. In particular, we compare residual stress measurements in S235JRC steel welds by means of neutron diffraction with high resolution magnetic field mappings. Results indicate a qualitative correlation between residual stresses and local stray field variation. In addition, stray field measurements of plastically deformed specimens for quasi- static and cyclic loading cases are discussed. The present study concludes that GMR sensors can detect inhomogeneous plastic deformations of S235JR steel in a very early stage, without specific signal processing according to the ISO 24497-1:3.