Magnetic Flux Leakage Inspection of Moving Steel Sheets
Date
1996
Authors
Shin, Young-Kil
Major Professor
Advisor
Committee Member
Journal Title
Journal ISSN
Volume Title
Publisher
Abstract
In the process of making drawn and ironed cans out of a steel sheet, non-metallic inclusions such as chemical oxides in the steel sheet may cause cracks. Therefore, steel sheets are inspected before they are drawn and the magnetic flux leakage testing is usually employed for the inspection [1]. When there are non-metallic inclusions in the steel sheet, magnetic fields produced by a magnetizer leak out around such defects because of the differences in material permeability. These leakage fields are detected by flux sensitive sensors such as Hall plates or magnetodiodes [2].
Series Number
Journal Issue
Is Version Of
Versions
Academic or Administrative Unit
Type
event
Comments
Rights Statement
Copyright
Mon Jan 01 00:00:00 UTC 1996