The AliveCor KardiaMobile ECG device allows electrocardiogram assessment in awake bonobos (Pan paniscus)

dc.contributor.author Olds, June E.
dc.contributor.author Goldacker, Ashley
dc.contributor.author Huneycutt, David
dc.contributor.author Huneycutt, Sarah P.
dc.contributor.author Taglialatela, Jared P.
dc.contributor.author Ward, Jessica
dc.contributor.department Department of Veterinary Clinical Sciences
dc.date.accessioned 2023-04-04T18:36:32Z
dc.date.available 2023-04-04T18:36:32Z
dc.date.issued 2023-04-04
dc.description.abstract OBJECTIVE To determine the diagnostic utility of a smartphone-based ECG device (Alivecor KardiaMobile) in awake bonobos (Pan paniscus). ANIMALS 7 adult bonobos in human care. PROCEDURES Bonobos were trained with positive reinforcement to hold 1 finger from each hand onto the KardiaMobile sensors for 30 seconds to obtain an ECG reading. Ten ECG tracings were recorded from each bonobo and evaluated by a veterinarian, a veterinary cardiologist, and a human cardiologist for tracing quality, tracing length, heart rate, identification of P-waves, and presence and quantification of premature ventricular or atrial contractions. RESULTS 6 of the 7 bonobos were trained within 21 weeks to allow the collection of 10 diagnostic quality ECG tracings. The average heart rate recorded was 87 bpm (range = 60 to 118 bpm). Potential abnormalities identified by the KardiaMobile included premature ventricular contractions in 2 male bonobos and 1 premature atrial contraction in another male. There was strong agreement by reviewers in all ECG parameters except for the identification of P-waves. CLINICAL RELEVANCE The Alivecor KardiaMobile device has diagnostic utility as a screening tool for use in bonobos in human care. The training was accomplished to yield diagnostic ECG readings of acceptable duration in awake bonobos. Given the prevalence of cardiovascular disease in great apes, this technology may identify a subset of great apes who may benefit from early intervention and treatment in an effort to delay the progression of cardiac disease.
dc.description.comments This article is published as Olds, June E., Ashley Goldacker, David Huneycutt, Sarah P. Huneycutt, Jared P. Taglialatela, and Jessica L. Ward. "The AliveCor KardiaMobile ECG device allows electrocardiogram assessment in awake bonobos (Pan paniscus)." American Journal of Veterinary Research (2023): 1-7. DOI: 10.2460/ajvr.23.01.0013. Copyright 2023 American Veterinary Medical Association. Attribution-NonCommercial 4.0 International (CC BY-NC 4.0). Posted with permission.
dc.identifier.uri https://dr.lib.iastate.edu/handle/20.500.12876/qzoDMgXw
dc.language.iso en
dc.publisher American Veterinary Medical Association
dc.source.uri https://doi.org/10.2460/ajvr.23.01.0013 *
dc.subject.disciplines DegreeDisciplines::Medicine and Health Sciences::Veterinary Medicine::Other Veterinary Medicine
dc.title The AliveCor KardiaMobile ECG device allows electrocardiogram assessment in awake bonobos (Pan paniscus)
dc.type article
dc.type.genre article
dspace.entity.type Publication
relation.isAuthorOfPublication 3050baf5-d1b2-4da9-8ae0-bedbafedcb99
relation.isOrgUnitOfPublication 1ad68def-86ae-460b-8808-f1b1febafd0a
File
Original bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
2023-WardJessica-AliveCor.pdf
Size:
10.44 MB
Format:
Adobe Portable Document Format
Description:
Collections