Abstract
Eddy current methods of flaw detection have been in use for many years. Frequencies used in this type of flaw detector normally range from tens of kilohertz to a few megahertz. We report on recent progress using a resonant probe which operates in the gigahertz frequency range, and compare its performance with classical eddy current methods.