Spray-on Transducers for High-Temperature Applications

Thumbnail Image
Date
2016-01-01
Authors
Ledford, Kenneth
Tien, Leland
Xu, Janet
Tittmann, Bernhard
Major Professor
Advisor
Committee Member
Journal Title
Journal ISSN
Volume Title
Publisher
Abstract

Monitoring the structural health of large valve bodies in high-temperature environments such as power plants faces several limitations: commercial transducers are not rated for such high-temperatures, gel couplants will evaporate, and measurements cannot be made in-situ. To solve this, we have furthered the work of Barrow and Kobayashi in applying a transducer in liquid form by making it more field-deployable; the sintering step is removed, the fabrication time is reduced, and the signal-to-noise ratio is improved using post-processing techniques. Bismuth Titanate (BiT) was used as the piezoelectric material for its high Curie temperature, and three separate chemical binders were demonstrated to work: sol-gel, potato starch, and a proprietary high-temperature inorganic binder (IB). The pros and cons of each chemical binder are compared with respect to substrate compatibility, stable operating temperature, and fabrication time. The BiT/IB combination is highlighted for its compatibility on both reactive and non-reactive substrates, stable operating temperature of 330oC, and quick fabrication time making it ideal for in-situ monitoring of large valve bodies.

Series Number
Journal Issue
Is Version Of
Versions
Academic or Administrative Unit
Type
event
Comments
Rights Statement
Copyright
Funding
DOI
Supplemental Resources
Source