Development of Thermal Performance Metrics for Direct Gas-Fired Circulating Heaters

Thumbnail Image
Date
2021-06-24
Authors
Smith, Benjamin
Major Professor
Advisor
Committee Member
Journal Title
Journal ISSN
Volume Title
Publisher
Abstract

Many climate-controlled agricultural buildings use direct gas-fired circulating heaters (DGFCH) for supplement heat. There is no standardized test to calculate thermal efficiency for these heaters. This study aimed to develop a measurement system and analytical analysis for thermal efficiency, quantify the measurement uncertainty, and assess economics of DGFCH efficiency. The measurement system developed was similar to the ASHRAE 103 standard test stand with adaptations to connect the apparatus to the DGFCH. Two different propane measurement systems were used: input ratings < 30 kW used a mass flow system and input ratings > 30 kW used a volumetric gas meter. Three DGFCHs (21.9, 29.3, 73.3 kW) were tested to evaluate the system. Thermal efficiencies ranged from 92.4% to 100.9%. The resulting uncertainty (coverage factor of 2; ~95% Confidence Interval) ranged from 13.1% to 30.7% for input ratings of 56.3 to 11.4 kW. Key sources of uncertainty were propane and mass flow of air measurement. The economic impact of 1% difference in thermal efficiency ranged from USD $61.3 to $72.0 per heating season. Refinement of the testing system and procedures are needed to reduce the uncertainty. The application of this system will aid building designers in selection of DGFCHs for various applications.

Series Number
Journal Issue
Is Version Of
Versions
Series
Type
article
Comments

This article is published as Smith, Benjamin C., Brett C. Ramirez, and Steven J. Hoff. "Development of Thermal Performance Metrics for Direct Gas-Fired Circulating Heaters." Agriculture 11, no. 7 (2021): 588. DOI: 10.3390/agriculture11070588. Posted with permission.

Rights Statement
Copyright
Fri Jan 01 00:00:00 UTC 2021
Funding
DOI
Supplemental Resources
Collections